Air Filter Size Finder for Florida Homes
Look up the filter from the air handler or furnace model number, using manufacturer installation manuals and spec sheets — not a guess and not a store SKU. If this lookup does not have that sheet, it says so. Then you read the old cardboard or measure the slot. A 20×25×1 is usually about 19.5×24.5×¾ in your hand. In Florida humidity, a dense 1-inch MERV 13 can ice a coil and leave the house clammy — MERV 8 or 11 is the safer everyday pick on a thin rack. Tool only. No shop phone.
Hard stop: This page does not invent missing Carrier or other furnace sizes. Unsourced families stay “sheet not in lookup.” Measure when the sheet is missing. No shop phone. Educational tool only.
Look up by model
No match? Measure
Printed numbers on the old filter are already the size to buy. Tape numbers are usually the smaller actual size.
What this lookup actually has
Only rows we pulled from a manufacturer IOM or spec sheet. If your model is not here, the tool will not invent a size.
| Family | What the sheet says | Source |
|---|---|---|
| Goodman / Amana / Daikin ARUF, ASPT, AVPTC, AMST, AWST | Factory filter rails: B cabinet 16×20×1, C 20×20×1, D 24×20×1 (D actual must be under 23½×20). Cabinet letter is after the capacity digits. Filter may instead be at a return grille. | Goodman ARUF/ASPT/AVPTC IOM §10 Return Air Filters. Daikin AMST U1400 series IOM, same cabinet rule. |
| Lennox CBA38MV | One 20×20×1 on -018/024/030/036. One 20×24×1 on -042/048/060. | Lennox IOM 507725-02, Table 4 Filter Dimensions. |
| York AHE / AHV (built-in 1″ rack) | Cabinet B 16×20×1, C 20×20×1, D 22×20×1. Last letter of the model is the cabinet. | York Air Handlers User’s Information Manual, Table 1. |
| Rheem / Ruud RH1T, RH2T and similar (no internal rack) | Sheet: no factory filter rack. If the RXHF filter base is installed: 17″ cabinet 16×20, 21″ 20×20, 24″ 25×20 (1″ or 2″). If the filter is only a wall grille, measure that grille. | Rheem product data, External Filter Base RXHF table; RH1T/RH2T IOM air-filter section. |
| Trane / American Standard TEM6 | Product data: filter not furnished; remote filter required. SlimFit box replacements (if that accessory is actually there): FLRSF1185 17.75×19.75, FLRSF1235 22.75×19.75. Otherwise measure. | Trane TEM6 product data (Filter Furnished? No) and SlimFit accessory list AHR-PSD006C-EN. |
| Carrier / Bryant / Payne KFAFR kit (FB4/FV4 class) | Only if the KFAFR rack is installed: 14″ → 12×20×1 (KFAFR0101FRM); 17″ → 16×20×1 (KFAFR0201FRM); 21″ → 20×20×1 (KFAFR0301FRM); 24″ → two 12×20×1 (KFAFR0401FRM). Capacity-to-cabinet mapping is not in this lookup — enter the kit part or cabinet width, or measure. | KFAFR installation instructions, Catalog AG-KFAFR-01, Table 1. |
| Goodman GMVC96 furnace | B-cabinet 0403/0603/0803: (1) 16×25 side or bottom. C/D 0804/1005/1205: (1) 20×25 bottom or (2) 16×25 side. Sheet says equal-or-greater and remote filters are allowed. | Goodman spec SS-GMVC96, Minimum Filter Sizes. |
| Amana AMVC96 / Goodman GMSS96 | Same pattern as GMVC96: B-cabinet (1) 16×25 side or bottom; C/D (1) 20×25 bottom or (2) 16×25 side. Minimums; remote OK. | SS-AMVC96 / SS-GMSS96 Minimum Filter Sizes. |
| Goodman GCSS96 (downflow) | 0402B/0603B/0804C: (2) 10×20 or (1) 16×25 top. 1005C/1205D: (1) 14×20 bottom or (1) 20×25 top. | SS-GMSS96, GCSS96 Minimum Filter Sizes. |
| Rheem R96V | External RXGF racks, 1-inch. Side almost always 15¾×25. Bottom 15¾ / 19¼ / 22¾ × 25 by input. Downflow 12×20 or 14×20. Racks ship without filters. | Rheem R96V product data, FILTER RACK FILTER SIZES. |
| Lennox ML296UHV / EL296UHV | No factory filter. Table 1 by cabinet: 17½″ 16×25×1; 21″ side 16×25×1 / bottom 20×25×1; 24½″ two 16×25×1 side / 24×25×1 bottom. | ML296 IOM 507869-03a TABLE 1; EL296UHV IOM TABLE 1 (same cabinet-width table). |
| Goodman GMVM97 / GCVM97 | GMVM97: 0603B/0803B/0804C/1005C (1) 16×25 side or bottom; 1205D (1) 20×25 bottom or (2) 16×25 side. GCVM97 downflow: 0603B/0803B/0804C (2) 10×20 or (1) 16×25 top; 1005C (2) 14×20 or (1) 20×25 top. Minimums. | SS-GMVM97 Minimum Filter Sizes. |
| Russell by Rheem S802V | RXGF racks: side 15¾×25. Bottom 15¾ / 19¼ / 22¾ × 25 by input (050/075317 vs 075421 & 100 vs 125). | S802V product data FORM GRR-546 REV. 1, FILTER RACK FILTER SIZES. |
| York TM9Y | Filters outside the cabinet. High-velocity recs by cabinet A–D (side 16×25 or two 16×25; bottom 14/16/20/22×25). | York TM9Y tech guide 5129599-YTG-C-1016. |
| Trane S9V2 (upflow) | Filter not furnished. Hi-vel bottom: B 16×25×1, C 20×25×1, D 24×25×1. Downflow not mapped here. | Trane S9V2 product data, FILTER section. |
| ICP F96VTN / G96VTN (Series B) | Table 9 by casing: 14″ side 16×25×¾ / bottom 14×25×¾; 17″ 16×25×¾ both; 21″ side 16×25×¾ / bottom 20×25×¾; 24½″ side 16×25×¾ / bottom 24×25×¾. Washable. Media cabinet (Table 10) 16/20/24 × 25 × ¾ or 4-5/16. | F96VTN/G96VTN Series B IOM, Table 9 and Table 10. Catalog FG96VTN2-01SI. ICP, a division of Carrier. Not used as a 59TP6 row. |
| Carrier 59TP6A | IOM Table 7 by casing: 14″ side 16×25×¾ / bottom 14×25×¾; 17½″ 16×25×¾ both; 21″ side 16×25×¾ / bottom 20×25×¾; 24½″ side 16×25×¾ / bottom 24×25×¾. Washable. Media cabinet is a separate table. | 59TP6A-03SI, Table 7. Not used for 59TP6C or 59SC5. |
| Carrier 59SU5A | Same Table 7 casing sizes as above (washable ¾-inch). | 59SU5A-03SI, Table 7. |
| Bryant 926T / 926S | Owner’s Table 1 is filter-cabinet height (16/20/24 → 16/20/24 × 25 × ¾ or 4-5/16). Measure the cabinet. Side return may differ. | Bryant 926T owner’s manual, Table 1. |
| Carrier 59SC5 / 59TP6C and other 59 letters | Not in this table. Field-supplied filter on product data. Will not copy 59TP6A Table 7 onto another letter. | Needs that series’ IOM Table 7. |
Nominal vs actual (when you have to measure)
Stores sell nominal sizes. The filter in your hand is usually about ¼ to ½ inch smaller so it slides. Buy the printed size. If the print is gone, measure and round up to the common nominal size.
MERV in Florida humidity
On a 1-inch slot, MERV 8 is the everyday pick and MERV 11 is fine on many blowers. MERV 13 in a thin 1-inch can cut airflow, freeze the coil, and leave the house clammy. A 4-inch media cabinet has more area, so higher MERV is more realistic there. Match the filter to the slot you actually have. Related: dirty filter / high-MERV freeze and AC freezing in Florida humidity.
Neighbor voice, not a shop pitch. Independent Florida tech framing (Apopka / Central Florida). Tools and checklists only. Call whoever you already trust — there is no shop phone on this page.
Common questions
How do I find what size air filter I need?
Try the indoor model against manufacturer IOM / product data first. Miss? Buy the printed size on the old cardboard. Print gone? Measure and round up to nominal. Example: tape ~19.5×24.5×¾ → buy 20×25×1.
Nominal vs actual — which do I buy?
Buy the printed nominal (20×25×1). Actual is smaller so it slides. Do not buy the tape numbers unless you used the measure path to convert them.
Can I use MERV 13 in a 1-inch Florida rack?
Often no. Dense 1-inch MERV 13 can starve airflow and ice a coil in Florida humidity. MERV 8–11 is the safer everyday pick on a thin rack; 4-inch media cabinets handle higher MERV better.
Why “no buy size” for my model?
Only sourced IOM rows print a size. Missing Carrier/other sheets stay honest misses. Measure, or wait until that sheet is added — we will not invent it.
Can I use a 4-inch filter in a 1-inch rack?
No. The rack is the rack. Media cabinets take 4–5 inch filters; 1-inch rails do not.
Also here
AC tonnage calculator · Florida AC maintenance checklist · AC freezing checklist · Dirty filter / high MERV · Outdoor coil clearance · Thermostat near supply vent · Closed doors & return air · Short cycling · Dehumidifier pint planner · Repair vs replace Florida AC · 3-ton vs 3.5-ton · SEER2 savings · Refrigerant guide · Tools hub. Tools and guides in this same set. Nobody’s advertising a shop here.
Sources (manufacturer rows + Florida context)
- Goodman ARUF / ASPT / AVPTC IOM §10 Return Air Filters (B/C/D cabinet rails); Daikin AMST U1400 IOM same cabinet rule. Furnace minimums: SS-GMVC96, SS-AMVC96, SS-GMSS96/GCSS96, SS-GMVM97.
- Lennox CBA38MV IOM 507725-02 Table 4; ML296UHV 507869-03a / EL296UHV TABLE 1 by cabinet width.
- York Air Handlers User’s Information Manual Table 1 (AHE/AHV); TM9Y tech guide 5129599-YTG-C-1016 recommended filter sizes.
- Rheem / Ruud RH1T–class IOM (no internal rack) + RXHF external filter base table; R96V / Russell S802V RXGF rack tables.
- Trane TEM6 product data (filter not furnished; SlimFit accessory actuals only if installed); S9V2 product data Hi-Vel upflow bottom sizes.
- Carrier/Bryant/Payne KFAFR AG-KFAFR-01 Table 1; Carrier 59TP6A-03SI / 59SU5A-03SI Table 7; ICP F96VTN/G96VTN Series B Table 9–10 (not cloned onto other 59 letters); Bryant 926T owner’s Table 1 (cabinet height).
- Florida MERV / freeze cluster on this site: dirty filter / high MERV, coil freeze. Competitor SERP notes in provenance (static charts + shop CTAs); we keep model+IOM honesty + Florida 1″ MERV caution.