TONNAGE CALCULATOR

Central Florida · size it for humidity

AC Tonnage Calculator for Florida Homes

Start with square feet and your nearest Florida city for an instant rule-of-thumb answer (about 22 BTU per square foot, not the old 1-ton-per-400 rule). Then open Refine for your house to add windows, walls, attic, and ducts. The same result box switches to a house-specific load and shows every line of the math. If you land between two sizes, the smaller one usually dehumidifies better here. Not Manual J.

Florida AC size calculator

Two inputs give an instant rule-of-thumb answer. Open “Refine for your house” to swap in a house-specific load with every line of the math shown. Same result box either way.

Refine for your house windows, walls, attic, ducts · about two minutes

Once this is open, the result switches from the rule of thumb to a house-specific load. Close it to go back.

Enter square feet to see an estimate.

Estimated cooling load

Show the math (BTU/h)

Planning estimate only. Not ACCA Manual J and not a quote.

Share link:

Rule of thumb vs house-specific: the quick answer uses a Florida-adjusted 22 BTU per square foot, the same for every house. The refined answer works out this house’s heat gain from city design weather (ACCA Manual J 8th ed. 1% dry bulb, coincident wet bulb, and design grains), windows, walls, attic, air leakage, people, and ducts. The two can differ by a ton or more, because it depends on the house. The 90–115% size window follows the Manual S idea that equipment should not be much bigger than the load. Use either to check a contractor’s number, not to replace a real load calc.

How this Florida calculator works

A ton of cooling is 12,000 BTU per hour. The calculator gives two answers in one box, and they can disagree because it depends on the house.

  • Quick rule of thumb (square feet only): about 22 BTU per square foot, roughly 545 sq ft per ton. National shortcuts like “1 ton per 400 square feet” push a lot of Florida houses too big. The rule of thumb is the same for every house of that size, so treat it as a ceiling check, not a design number.
  • Refined for your house: adds up heat through windows (by glass type, direction, and shade), walls, the ceiling under a hot attic, outside air leaking in, people, appliances, and duct gain, using your city’s design-day temperature and humidity. Newer homes with low-E glass, good attic insulation, and sealed ducts often come in a ton or more below the rule of thumb. Older, leaky, west-facing homes can come in above it.

Equipment sizes are shown as a 90–115% window around the load, because residential equipment is sold in half-ton steps (1.5, 2, 2.5, 3, 3.5, 4, 5).

Why Florida humidity changes the answer

Florida air is not just hot. It is wet. A large share of what an AC does in July and August is pull moisture, not just drop the thermostat. That only happens when the system runs long enough for the coil to get cold and stay there.

An oversized unit cools the air fast, hits setpoint, and shuts off. Indoor air can feel chilly and still sticky. You also get more short-cycling, which is hard on compressors. If this calculator puts you between two sizes, the smaller one is often the better Florida choice after a real Manual J — not a bigger “just in case” unit.

Example results: rule of thumb vs house-specific

Outputs of this calculator for Orlando, one story, 8 ft ceilings. “Typical” means double-pane clear glass, block walls with furring, R-30 attic, dark shingle roof, average air leakage, typical attic ducts, four people. These are examples, not a promise about your house.

HouseRule of thumbRefined loadSizes that fit
1,200 sq ft, typicalAbout 2 tons1.79 tons2 ton
1,800 sq ft, typicalAbout 3.5 tons2.40 tons2.5 ton
2,000 sq ft, typicalAbout 3.5 tons2.61 tons2.5 ton
2,400 sq ft newer build (tight, low-E, R-38, sealed ducts)About 4.5 tons1.94 tons2 ton
2,000 sq ft older (leaky, single-pane west glass, no shade, R-19, old ducts)About 3.5 tons4.83 tons5 ton (get a real Manual J first)

Same square footage, a two-ton swing. That is why the refined inputs matter more than the size of the house.

What a real Manual J adds

  • Every wall, window, and door measured room by room, not whole-house averages
  • Exact glass SHGC and overhang geometry for each window
  • Measured duct leakage and duct runs (hot Florida attics punish leaky ducts)
  • Blower-door infiltration instead of an age-based guess
  • Room-by-room loads so airflow can be balanced

Tonnage alone is not the whole job. Airflow, duct static, and whether the house needs help with humidity (runtime, coil temperature, sometimes a whole-home dehumidifier) all matter.

Common questions

How many square feet per ton in Florida?

The rule of thumb here is about 545 sq ft per ton. House-specific results commonly run 600–1,200 sq ft per ton for newer, well-insulated homes and closer to 400–500 for older, leaky, sunny ones. It depends on the house. 400 sq ft per ton is a common internet number and it oversizes a lot of Florida houses.

What size AC for 2,000 square feet in Florida?

The quick rule of thumb says about 3.5 tons. Refined for a typical Orlando house it is closer to 2.6 tons of load (2.5 ton equipment). A newer tight house can drop to about 2 tons, and an older leaky west-facing one can push toward 5. Confirm with Manual J before you shop. Longer answer: what size AC for 2,000 sq ft in Florida.

Is a bigger AC better in Florida heat?

Usually no. Bigger is not more comfortable here. Runtime is what dries the air. See 3 ton versus 3.5 ton in Florida humidity.

Can I use this to buy a system online?

Please don’t. Wrong tonnage is expensive to undo, and Florida code and manufacturer warranties expect a proper load calculation.

Next, not a sales pitch

If you are replacing a unit, take this range to a contractor and ask to see the Manual J, not just a square-footage guess. If you are a tech, treat 22 BTU/sq ft as a Florida-aware ceiling check, use the refined inputs for a closer number, then let the real load calc win.

Also: SEER2 savings calculator using your region’s planning hours and rate (cooling kWh only).

These pages are free planning tools. Google AdSense may show ads. There is no contractor phone and no booking form.